No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
L2VPN_1.3.6.1.4.1.2011.5.25.119.1.2.8 hwVplsVcStatusChange

L2VPN_1.3.6.1.4.1.2011.5.25.119.1.2.8 hwVplsVcStatusChange

Description

The status of the VPLS VC changed. (VsiName=[VsiName], PwId=[PwId], RemoteIp=[RemoteIp], HWL2VpnStateChangeReason=[HWL2VpnStateChangeReason], HWPwState=[HWPwState], HWPwWorkingState=[HWPwWorkingState], SysUpTime=[SysUpTime])

The VPLS VC status changed.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwVplsVcStatusChange

Trap OID

1.3.6.1.4.1.2011.5.25.119.1.2.8

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter Description

VsiName

VSI name

PwId

VPLS PW ID

RemoteIp

IP address of the remote peer

HWL2VpnStateChangeReason

Reason of the VC status change

HWPwState

VC status:
  • up
  • down

HWPwWorkingState

VC working status:
  • work
  • protect

SysUpTime

Startup time of the system

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.119.1.1.8

hwVplsStateChangeReason

N/A

1.3.6.1.4.1.2011.5.25.119.1.1.5.1.13

hwVplsPwState

hwVplsVsiName;

hwVplsPwID;

hwVplsPwRemoteIp;

1.3.6.1.4.1.2011.5.25.119.1.1.5.1.14

hwVplsPwWorkingState

hwVplsVsiName;

hwVplsPwID;

hwVplsPwRemoteIp;

Impact on the System

If the VPLS VC goes Down, the VPLS service will be interrupted. The VPLS service recovers after the VPLS VC goes Up again.

Possible Causes

Cause 1: The VPLS VC went Down.

Cause 2: The VPLS VC went Up.

Cause 3: The working status of the VPLS VC changed from work to protect.

Cause 4: The working status of the VPLS VC changed from protect to work.

Procedure

  • This trap message is informational only, and no action is required.
Translation
Download
Updated: 2019-04-02

Document ID: EDOC1100074754

Views: 17226

Downloads: 25

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share