Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DAD_1.3.6.1.4.1.2011.5.25.246.1.3 hwDadPortProtocolAlarm

DAD_1.3.6.1.4.1.2011.5.25.246.1.3 hwDadPortProtocolAlarm

Description

The protocol status of the dual-active port is down.(hwDadDetectPort=[hwDadDetectPort])

The protocol status of the dual-active detection (DAD) port is Down.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwDadPortProtocolAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.246.1.3

Alarm ID

0x09a92003

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DAD_1.3.6.1.4.1.2011.5.25.246.1.4 hwDadPortProtocolAlarmResume

Parameters

Name Meaning

hwDadDetectPort

Indicates the DAD port.

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.246.3.1.1

hwDadDetectPort

N/A

Impact on the System

The DAD function may fail to take effect after the stack splits.

Possible Causes

The DAD port is physically Down or cannot properly send or receive packets.

Procedure

  1. Run the display dual-active command to check whether the physical status of the DAD port is Up.

    • If not, troubleshoot the Down failure.

    • If so, go to step 2.

  2. Collect the trap, log, and configuration information, and then contact technical support personnel.