Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.157.2.304 hwFlowControlDeadLockAlarmResume

DEVM_1.3.6.1.4.1.2011.5.25.157.2.304 hwFlowControlDeadLockAlarmResume

Description

The port recovered and did not receive pause frames.(IfIndex=[hwPhysicalPortIfIndex], IfName=[hwPhysicalPortName])

The port recovered and did not receive pause frames.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwFlowcontrolDeadLock

Trap OID

1.3.6.1.4.1.2011.5.25.157.2.304

Alarm ID

0x08132233

Alarm Type

communicationsAlarm

Raise or Clear

Clear

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.157.2.303 hwFlowControlDeadLockAlarm

Parameters

Parameter

Description

IfIndex

Physical interface index.

IfName

Physical interface name.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.1

hwPhysicalPortIfIndex

hwPhysicalPortIfIndex

1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4

hwPhysicalPortName

hwPhysicalPortIfIndex

Impact on the System

Services are not affected.

Possible Causes

Flow control was disabled on the port, or the rate of pause frames received by the port within a period of time was lower than eighty percent of the threshold.

Procedure

  1. The trap is informational only, and no action is required.