No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.27 hwStackChipSingleHomedAlarm

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.27 hwStackChipSingleHomedAlarm

Description

In the dual-homing network, two ports of any chip on the dual-chip leaf switch are connected to a spine switch. (hwStackLeafMemberId=[hwStackLeafMemberId], Reason=[Reason])

When a CE5810-48T4S-EI is dual-homed to two parent switches, two ports of a forwarding chip are connected to the same parent switch.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwStackChipSingleHomedAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.27

Alarm ID

0x09da2000

Alarm Type

environmentalAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.28 hwStackChipSingleHomedAlarmResume

Parameters

Parameter Meaning

hwStackLeafMemberId

Indicates the ID of the leaf switch.

Reason

Indicates the alarm cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.11

hwStackLeafMemberId

N/A

Impact on the System

Uplink traffic of leaf switches may be forwarded through the stack link of the parent switch.

Possible Causes

When a CE5810-48T4S-EI is dual-homed to two parent switches, two ports of a forwarding chip are connected to the same parent switch. 10GE1/0/1 and 10GE1/0/2 reside on the same forwarding chip; 10GE1/0/3 and 10GE1/0/4 reside on the same forwarding chip.

Procedure

  1. Connect the two ports on the same forwarding chip to different parent switches.