Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
TRUNK_1.3.6.1.4.1.2011.5.25.41.3.28 hwExtAllMemberDownNotify

TRUNK_1.3.6.1.4.1.2011.5.25.41.3.28 hwExtAllMemberDownNotify

Description

The last member interface link status changes to down. (TrunkIfIndex=[INTEGER], TrunkName=[OCTET])

The last member interface of an Eth-Trunk interface in static LACP mode went Down.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwExtAllMemberDownNotify

Trap OID

1.3.6.1.4.1.2011.5.25.41.3.28

Alarm ID

0x00F10263

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

TRUNK_1.3.6.1.4.1.2011.5.25.41.3.29 hwExtAllMemberDownResume

Parameters

Parameter

Description

TrunkIfIndex

Trunk interface index

TrunkName

Name of the Trunk interface

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.2.1.31.1.1.1.1

ifName

ifIndex

Impact on the System

The interface cannot forward packets normally.

Possible Causes

All the member interfaces of the Eth-Trunk interface in static LACP mode were Down.

Procedure

  1. Run the display this command in the Trunk interface view to check whether the Trunk interface is shut down.

    • If the Trunk interface is shut down, go to Step 2.
    • If the Trunk interface is not shut down, go to Step 3.

  2. Run the undo shutdown command in the Trunk interface view to check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 8.
    • If the alarm is not cleared, go to Step 3.

  3. Run the display this command in the view of each Eth-Trunk member interface to check whether the member interface is shut down.

    • If the member interface is shut down, go to Step 4.
    • If the member interface is not shut down, go to Step 5.

  4. Run the undo shutdown command in the member interface view to check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 8.
    • If the alarm is not cleared, go to Step 5.

  5. Check whether the cable and optical module are loosened or dropped.

    • If the cable and optical module are loosened or dropped, go to Step 7.
    • If the cable and optical module are not loosened or dropped, go to Step 6.

  6. Connect the physical link correctly and then check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 8.
    • If the alarm is not cleared, go to Step 7.

  7. Collect alarm information and configuration information, and then contact technical support personnel.
  8. End.