Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FCOE_1.3.6.1.4.1.2011.5.25.303.2.4 hwFCoELoginVnNum

FCOE_1.3.6.1.4.1.2011.5.25.303.2.4 hwFCoELoginVnNum

Description

The number of online VN_Ports mapping the VF_Port has already reached the maximum (instance name=[instanceName] , VF_Index=[vfPort] , VN_Port quantity=[vnPortNum] ).

The number of VN_Ports of the VF_Port has reached the maximum.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwFCoELoginVnNum

Trap OID

1.3.6.1.4.1.2011.5.25.303.2.4

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

instanceName

Name of the instance.

vfPort

Index of the VF_Port.

vnPortNum

Number of VN_Ports.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.303.1.3

hwFCoEPortResource

N/A

Impact on the System

New VN_Ports cannot log in to the VF_Port.

Possible Causes

After the number of VN_Ports of the VF_Port has reached the maximum, some VN_Ports still send login requests to the VF_Port.

Procedure

  • Stop creating VN_Ports on the ENode.
  • Adjust the networking and reduce the number of ENodes.