Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BFD for OSPF

BFD for OSPF

Definition

Bidirectional Forwarding Detection (BFD) is a mechanism to detect communication faults between forwarding engines.

To be specific, BFD detects connectivity of a data protocol on a path between two systems. The path can be a physical link, a logical link, or a tunnel.

In BFD for OSPF, a BFD session is associated with OSPF. The BFD session can quickly detect a link fault and then notify OSPF of the fault. This speeds up OSPF's response to the change of the network topology.

Purpose

A link fault or a topology change may cause devices to re-calculate routes. Therefore, the convergence of routing protocols must be as quick as possible to improve the network performance.

Link faults are unavoidable. Therefore, a feasible solution is required to detect faults fast and notify routing protocols of the faults immediately. With BFD being associated with OSPF, once a fault occurs on a link between neighbors, BFD can speed up the OSPF convergence.

Table 5-11 Comparison before and after BFD for OSPF is enabled

Associated with BFD

Link Fault Detection Mechanism

Convergence Speed

No

An OSPF dead timer expires. The default value of the dead timer is 40s.

At the second level

Yes

A BFD session goes Down.

At the millisecond level

Implementation

Figure 5-8 BFD for OSPF

Figure 5-8 shows the implementation of BFD for OSPF.

  1. OSPF neighbor relationships are established between three routers.

  2. After the status of a neighbor relationship reaches Full, BFD is instructed to establish a BFD session.

  3. The outbound interface from Router A to Router B is GE 2/0/0. When the link fails, BFD immediately detects the fault and then notifies Router A of the fault.

  4. Router A processes the event that a neighbor relationship becomes Down and re-calculates routes. After calculation, the outbound interface becomes GE 1/0/0 on Router C. Traffic from Router A passes through Router C to get to Router B.