Configuration Guide - Network Management and Monitoring

CloudEngine 12800 and 12800E V200R005C10

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, LLDP, NQA, Service Diagnosis, Mirroring, Packet Capture, sFlow, and NETCONF.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the NQA Client to Send Traps When a Test Fails

Configuring the NQA Client to Send Traps When a Test Fails

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run nqa test-instance admin-name test-name

    The NQA view is displayed.

  3. Run send-trap testfailure

    The NQA client is configured to send traps when the test fails.

    By default, the NQA client sends no trap when an NQA test fails.

  4. Run test-failtimes times

    The threshold on the traps sent after the NQA test fails is configured. This threshold specifies the maximum number of continuous test failures for the NQA test instance.

    By default, a trap is sent for each test failure.

  5. Run commit

    The configuration is committed.