Configuration Guide - Network Management and Monitoring

CloudEngine 12800 and 12800E V200R005C10

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, LLDP, NQA, Service Diagnosis, Mirroring, Packet Capture, sFlow, and NETCONF.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Condition of Triggering iPCA Performance Alarm

Configuring the Condition of Triggering iPCA Performance Alarm

Context

If the network administrator is unaware of network performance degradation and does not adjust services on the network in a timely manner, the number of lost packets and delay will continuously increase, causing user experience to degrade. To facilitate network operation and maintenance, the network O&M personnel can configure the condition of triggering iPCA performance alarms. When the number of lost packets or delay reaches the specified threshold, the alarm or clear alarm for packet loss or delay is reported.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run nqa ipfpm mcp

    The IPFPM-MCP view is displayed.

  3. Run instance instance-id

    The IP FPM measurement instance view is displayed.

  4. Run loss-measure ratio-threshold upper-limit upper-limit lower-limit lower-limit

    The upper and lower thresholds for IP FPM packet loss alarm and clear alarm are set.

  5. Configure the threshold for the IP FPM delay alarm.

    • If the target flow is a unidirectional flow, run the delay-measure one-way delay-threshold upper-limit upper-limit lower-limit lower-limit command to set the upper and lower thresholds for the IP FPM unidirectional delay alarm and clear alarm.
    • If the target flow is a bidirectional flow, run the delay-measure two-way delay-threshold upper-limit upper-limit lower-limit lower-limit command to set the upper and lower thresholds for the IP FPM bidirectional delay alarm and clear alarm.

  6. Run commit

    The configuration is committed.