Configuration Guide - Network Management and Monitoring

CloudEngine 12800 and 12800E V200R005C10

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, LLDP, NQA, Service Diagnosis, Mirroring, Packet Capture, sFlow, and NETCONF.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Verifying the IPv6 Flexible Flow Configuration

Verifying the IPv6 Flexible Flow Configuration

Context

You can run commands to verify that flexible flow statistics exporting has been configured correctly.

Procedure

  • Run the display forward enp [ slot slot-id ] command to check whether the card performs NetStream sampling in enhanced mode.

    NOTE:

    The CE12800E configured with ED-E, EG-E, and EGA-E series cards does not support this command.

  • Run the display netstream cache ipv6 record record-name [ { inbound | outbound } | destination interface interface-type interface-number | destination ipv6 ipv6-address | destination port port-number | source interface interface-type interface-number | source ipv6 ipv6-address | source port port-number | flowlabel flowlabel | protocol protocol-type | tos tos-number ] * slot slot-id [ chip chip-id ] [ verbose ] command to check detailed NetStream statistics on IPv6 flexible flows on the card.

    NOTE:

    Only the CE12800E configured with ED-E, EG-E, and EGA-E series cards supports the chip chip-id parameter.

  • Run the display netstream export ipv6 template command to check the exported template information.
  • Run the display netstream statistics ipv6 slot slot-id [ chip chip-id ] command to check NetStream statistics about IPv6 flows on the card.

    NOTE:

    Only the CE12800E configured with ED-E, EG-E, and EGA-E series cards supports the chip chip-id parameter.

  • Run the display netstream { all | global | interface interface-type interface-number } command to check the NetStream configuration.
Translation