Configuration Guide - Network Management and Monitoring

CloudEngine 12800 and 12800E V200R005C10

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, LLDP, NQA, Service Diagnosis, Mirroring, Packet Capture, sFlow, and NETCONF.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Rollback on Error

Rollback on Error

The rollback on error capability allows the device to perform rollback when an error occurs. More specifically, the <error-option> parameter of the <edit-config> operation can carry the rollback-on-error field. If an error occurs and error element <rpc-error> is generated during the <edit-config> operation, the server stops the <edit-config> operation and restores the configuration to the state before the <edit-config> operation.

This capability is only available when the device supports the candidate configuration capability.

Capability ID

<capability>urn:ietf:params:netconf:capability:rollback-on-error:1.0</capability>
  • RPC request:

    <rpc message-id="101" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
      <edit-config>
        <target>
          <running/>
        </target>
        <error-option>rollback-on-error</error-option>
        <config>
          <ifm xmlns="http://www.huawei.com/netconf/vrp" content-version="1.0" format-version="1.0">
            <interfaces>
              <interface>
                <name>10GE1/0/1</name>
                <mtu>100000</mtu>
              </interface>
            </interfaces>
          </ifm>
        </config>
      </edit-config>
    </rpc>
  • RPC reply:

    <rpc-reply message-id="101" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0"> 
      <ok/>
    </rpc-reply>