Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Data to Be Sampled

Configuring the Data to Be Sampled

When you configure Telemetry static subscription to the data sampled, you need to create a sampling sensor group and specify a sampling path and filter criteria.

Context

When static subscription is configured, a device functions as a client and a collector functions as a server. To statically subscribe to the data sampled, you need to configure a source of the data to be sampled.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run telemetry

    The Telemetry view is displayed.

  3. Run sensor-group sensor-name

    A sampling sensor group is created, and the Sensor-group view is displayed.

    By default, no sampling sensor group is created.

  4. Run sensor-path path [ condition express op-field field op-type op op-value value [ { and | or } op-type op op-value value ] ]

    A sampling path is configured for the Telemetry sensor group.

    By default, no sampling path is configured for the Telemetry sensor group.

    NOTE:

    A maximum of five paths can be configured for a sampling sensor group using this command.

    A sampling path name can be configured in a maximum of 10 sampling sensor groups at the same time. When the number of sampling paths reaches the upper limit, the device displays a message indicating that the maximum number of paths is reached.

    If the sampling sensor group is subscribed and configured with redundancy suppression, sampling paths with filter criteria specified cannot be configured in this sampling sensor group.

  5. Run commit

    The configuration is committed.