Configuration Guide - Network Management and Monitoring

CloudEngine 12800 and 12800E V200R005C10

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, LLDP, NQA, Service Diagnosis, Mirroring, Packet Capture, sFlow, and NETCONF.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Licensing Requirements and Limitations for iPCA

Licensing Requirements and Limitations for iPCA

Involved Network Elements

Other network elements are required to support iPCA.

Licensing Requirements

iPCA is a basic feature of a switch and is not under license control.

Version Requirements

Table 15-4 Products and minimum version supporting iPCA

Product

Minimum Version Required

CE12800E (configured with ED-E, EG-E, or EGA-E series cards)

V200R002C50

Feature Limitations

  • The prerequisite for packet loss and delay measurement is time synchronization among all devices. Therefore, before configuring iPCA on edge devices of a network, configure the Network Time Protocol (NTP) or 1588v2 on the devices.
    • If 1588v2 has been deployed on a network, it is the best choice for periodic time synchronization in iPCA.

    • To implement unidirectional delay measurement, configure the precise time synchronization protocol, 1588v2.

  • The measurement instance parameters of a DCP must be the same as the parameters of the same measurement instance on the MCP; otherwise, the DCP cannot send statistics data to the MCP.
  • Packet loss measurement and delay measurement cannot use the same color bit. Before you specify a color bit, ensure that this bit is not occupied by other services.
  • In performance measurement for VXLAN:
    • Both ends of a VXLAN tunnel must be configured as the TLPs when you collect packet statistics on this VXLAN tunnel.
    • A measurement instance cannot cover both IP and VXLAN networks.
  • End-to-end performance measurement can be configured on eSight, but hop-by-hop performance measurement cannot be configured on eSight.