Configuration Guide - Network Management and Monitoring

CloudEngine 12800 and 12800E V200R005C10

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, LLDP, NQA, Service Diagnosis, Mirroring, Packet Capture, sFlow, and NETCONF.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Licensing Requirements and Limitations for the OpenFlow Agent

Licensing Requirements and Limitations for the OpenFlow Agent

Involved Network Elements

The following devices participate in OpenFlow connection establishment:
  • Controller

    Switches can set up OpenFlow connections with the Agile Controller-DCN.

  • OpenFlow switch

    The switch must support the OpenFlow connection function.

Licensing Requirements

OpenFlow Agent is a basic feature of a switch and is not under license control.

Version Requirements

Table 5-2 Products and minimum version supporting OpenFlow Agent

Product Model

Minimum Version Required

CE12804/CE12808/CE12812/CE12816

V100R003C10

CE12804S/CE12808S

V100R005C00

CE12800E

V200R002C50

Feature Limitations

  • The Agile Controller in this document is the Agile Controller-DCN.

  • Huawei CE series switches can only function as OpenFlow-compatible switches, and can set up OpenFlow connections with the Agile Controller-DCN, but not third-party controllers.

  • In V200R003C00 and earlier versions, switches can set up OpenFlow connections with the Agile Controller only in an admin-VS. Since V200R003C00, switches can set up OpenFlow connections with the Agile Controller in any VS.

  • In V100R005C10 and earlier versions, the switches only support the EXPERIMENTER entry carrying the VXLAN service information. Since V100R006C00, switches support user policy tables.

  • Since V100R006C00, switches can set up OpenFlow connections with the Agile Controller through the VPN.

  • If the OpenFlow connection between the switch and Agile Controller is encrypted using SSL, the OpenFlow connection needs to be rebuilt after active/standby switchover.