Configuration Guide - Network Management and Monitoring

CloudEngine 12800 and 12800E V200R005C10

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, LLDP, NQA, Service Diagnosis, Mirroring, Packet Capture, sFlow, and NETCONF.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Licensing Requirements and Limitations for NQA

Licensing Requirements and Limitations for NQA

Involved Network Elements

Other network elements are not required.

Licensing Requirements

The NQA IPv4 function is a basic feature of CE12800 and CE12800E series switches and is not under license control.

The NQA IPv6 function can be used only after the IPv6 feature is enabled, whereas the IPv6 feature is under license control. By default, the IPv6 feature is disabled on newly purchased CE12800 and CE12800E series switches. To use the IPv6 feature, apply for and purchase the license from the equipment supplier.

Version Requirements

Table 7-1 Products and minimum version supporting NQA
Product Model Minimum Version Required
CE12804/CE12808/CE12812 V100R001C00
CE12816 V100R003C00
CE12804S/CE12808S V100R005C00
CE12800E V200R002C50

Feature Limitations

  • The CE12800E does not support LSP Ping and LSP Trace test instances.
  • The type of a running test instance cannot be changed. If you change the type of a running NQA test instance, the test instance will fail.
  • If the number of running test instances reaches the maximum value defined by the system, the start command is invalid.

  • When NQA is associated with VRRP, static route, and policy-based routing, the NQA test instance type must be ICMP.