No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - Device Management

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document describes the configurations of Device Management, including device status query, hardware management, Information Center Configuration, NTP, Synchronous Ethernet Configuration, Fault Management Configuration, Energy-Saving Management Configuration, Performance Management Configuration, Maintenance Assistant Configuration, and OPS Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Alarm Reporting Delay Function

Configuring the Alarm Reporting Delay Function

Context

When an alarm is reported repeatedly, users cannot efficiently locate faults. After the alarm reporting delay function is enabled and the delay is configured, a large number of invalid alarms are prevented from being reported.

After the alarm reporting delay function is enabled,

  • If no clear alarm is generated during the period, the alarm is reported to the NMS when the period expires.
  • If a clear alarm is generated during this period, the alarm and its clear alarm are both deleted from the alarm queue and will not be reported to the NMS.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run alarm

    The alarm view is displayed.

  3. Run delay-suppression enable

    The alarm reporting delay function is enabled.

    By default, the alarm reporting delay function is enabled.

  4. (Optional) Run suppression alarm alarm-name { cause-period cause-seconds | clear-period clear-seconds }

    The delay in reporting alarms is configured.

    The system defines a default delay in reporting alarms.

    To set the delay in reporting an active alarm, select the cause-period parameter. To set the delay in reporting a clear alarm, select the clear-period parameter.

  5. Run commit

    The configuration is committed.