Configuration Guide - Network Management and Monitoring

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, NETCONF, OpenFlow, LLDP, NQA, Mirroring, Packet Capture, Packet Trace, Path and Connectivity Detection Configuration, NetStream, sFlow, and iPCA.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Distinct Startup

Distinct Startup

The distinct startup capability indicates that the device can independently start. More specifically, the device can distinguish the <running/> configuration database from the <startup/> configuration database.

The NETCONF server must independently maintain the running configuration and be able to restore the running configuration after the device restarts. Operations on the <running/> configuration database cannot be automatically synchronized to the <startup/> configuration database and can only be updated to the <startup/> configuration database through a synchronization operation from the <running/> configuration database to the <startup/> configuration database (such as a <copy-config> operation).

Capability ID

<capability>urn:ietf:params:netconf:capability:startup:1.0</capability>

Perform the <copy-config> operation to copy the configuration data in the <running/> configuration database to the <startup/> configuration database:

  • RPC request:

    <rpc message-id="101" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
      <copy-config>
        <source>
          <running/>
        </source>
        <target>
          <startup/>
        </target>
      </copy-config>
    </rpc>
    
  • RPC reply:

    <rpc-reply message-id="101" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
      <ok/>
    </rpc-reply>