No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - Network Management and Monitoring

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, NETCONF, OpenFlow, LLDP, NQA, Mirroring, Packet Capture, Packet Trace, Path and Connectivity Detection Configuration, NetStream, sFlow, and iPCA.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the NQA Client to Send Traps After a Probe Succeeds

Configuring the NQA Client to Send Traps After a Probe Succeeds

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run nqa test-instance admin-name test-name

    The NQA view is displayed.

  3. Run send-trap testcomplete

    The NQA client is configured to send traps when a probe succeeds.

    By default, the NQA client sends no trap when a probe succeeds.

    NOTE:

    This command cannot be configured when the test-type is set to jitter.

  4. Run commit

    The configuration is committed.

Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100075365

Views: 33811

Downloads: 121

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next