Configuration Guide - Network Management and Monitoring

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, NETCONF, OpenFlow, LLDP, NQA, Mirroring, Packet Capture, Packet Trace, Path and Connectivity Detection Configuration, NetStream, sFlow, and iPCA.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Verifying the Basic SNMPv1 Function Configuration

Verifying the Basic SNMPv1 Function Configuration

Prerequisites

The configurations of basic SNMPv1 functions are complete.

Procedure

  • Run the display snmp-agent community [ read | write ] command to check community names.
  • Run the display snmp-agent sys-info version command to check the enabled SNMP version.
  • Run the display acl { acl-number | name acl-name | all } command to check ACL rules.
  • Run the display snmp-agent mib-view [ exclude | include | viewname view-name ] command to check MIB views.
  • Run the display snmp-agent mib modules command to check information about loaded MIB files.
  • Run the display snmp-agent sys-info contact command to check the administrator's contact information.
  • Run the display snmp-agent sys-info location command to check the location of the switch.
  • Run the display current-configuration | include max-size command to check the maximum size of an SNMP packet that can be sent and received by the device.
  • Run the display current-configuration | include trap command to check the configuration of the trap function.
  • Run the display snmp-agent trap all command to check current and default status of all traps of all features.
  • Run the display snmp-agent vacmgroup command to check all the configured View-based Access Control Model (VACM) groups.
  • Run the display snmp-agent target-host command to check information about the target host.
  • Run the display snmp-agent notify-filter-profile profile-name command to check the configurations of the filtered traps.