Configuration Guide - Network Management and Monitoring

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, NETCONF, OpenFlow, LLDP, NQA, Mirroring, Packet Capture, Packet Trace, Path and Connectivity Detection Configuration, NetStream, sFlow, and iPCA.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling a Switch to Perform sFlow Sampling in Enhanced Mode

Enabling a Switch to Perform sFlow Sampling in Enhanced Mode

Context

A switch can perform sFlow sampling in either of the following two modes:
  • Non-enhanced mode: A switch uses the CPU for sFlow sampling, which greatly affects CPU performance.
  • Enhanced mode: A switch uses CPU built-in chip for sFlow sampling, which therefore does not affect CPU performance and improves sFlow performance.

The CE6875EI supports sFlow sampling in enhanced mode, which improves sFlow performance. When sFlow sampling is performed in enhanced mode, the recommended sFlow sampling rate is 1/2k; otherwise, the recommended sFlow sampling rate is 1/10k.

NOTE:

Only CE6875EI supports the assign forward enp sflow enable command.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run assign forward enp sflow enable slot slot-id

    The switch is enabled to perform sFlow sampling in enhanced mode.

    By default, a switch performs sFlow sampling in non-enhanced mode; that is, a switch uses the CPU for sFlow sampling.

    NOTE:
    • When a switch performs sFlow sampling in enhanced mode, the switch cannot send sFlow packets through the management interface.

    • If both the assign forward enp sflow enable and assign forward enp netstream enable commands are run, the later one overwrites the previous one.

    • This command takes effect after the switch is restarted.

  3. Run commit

    The configuration is committed.