This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, NETCONF, OpenFlow, LLDP, NQA, Mirroring, Packet Capture, Packet Trace, Path and Connectivity Detection Configuration, NetStream, sFlow, and iPCA.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Licensing Requirements and Limitations for Path/Connectivity Detection

Licensing Requirements and Limitations for Path/Connectivity Detection

Involved Network Elements

To provide the path detection function, the switch must work with an Agile Controller-DCN. The AC sends detection packets through OpenFlow Packet-out messages, and the switch sends detection packets through OpenFlow Packet-in messages.

Licensing Requirements

Path/connectivity detection is a basic feature of a switch and is not under license control.

Version Requirements

Connectivity detection

Table 13-2 Products and minimum version supporting path detection

Product Model

Minimum Version Required

CE8868EI/CE8861EI

V200R005C10

CE8860EI/CE8850-32CQ-EI

V200R002C50

CE8850-64CQ-EI

V200R005C00

CE7850EI/CE7855EI

V200R002C50

CE6850HI/CE6850U-HI/CE6851HI/CE6855HI/CE6856HI/CE6870-24S6CQ-EI/CE6870-48S6CQ-EI/CE6870-48T6CQ-EI/CE6860EI

V200R002C50

CE6857EI

V200R005C10

CE6875EI/CE6880EI

V200R003C00

CE6865EI

V200R005C00

CE5880EI

V200R005C10

OAM-based IPv4 path detection

Table 13-3 Products and minimum version supporting path detection

Product Model

Minimum Version Required

CE8860EI

V200R001C00

CE8850-32CQ-EI

V200R002C50

CE8850-64CQ-EI

V200R005C00

CE7850EI/CE7855EI

V200R001C00

CE6850HI/CE6850U-HI/CE6851HI/CE6855HI/CE6870-24S6CQ-EI/CE6870-48S6CQ-EI

V200R001C00

CE6870-48T6CQ-EI/CE6880EI/CE6860EI/CE6856HI

V200R002C50

CE6875EI

V200R003C00

CE5880EI

V200R005C10

DSCP-based IPv4 path detection
Table 13-4 Products and minimum version supporting path detection

Product Model

Minimum Version Required

CE8868EI/CE8861EI

V200R005C10

CE8860EI

V200R003C00

CE8850-32CQ-EI

V200R003C00

CE8850-64CQ-EI

V200R005C00

CE7850EI/CE7855EI

V200R003C00

CE6850HI/CE6850U-HI/CE6851HI/CE6855HI/CE6856HI/CE6870-24S6CQ-EI/CE6870-48S6CQ-EI

V200R003C00

CE6857EI

V200R005C10

CE6870-48T6CQ-EI/CE6880EI/CE6860EI

V200R003C00

CE6875EI

V200R003C00

CE6865EI

V200R005C00

CE5880EI

V200R005C10

DSCP-based IPv6 path detection
Table 13-5 Products and minimum version supporting path detection

Product Model

Minimum Version Required

CE8868EI/CE8861EI

V200R005C10

CE8860EI

V200R005C00

CE8850-32CQ-EI

V200R005C00

CE8850-64CQ-EI

V200R005C00

CE7850EI/CE7855EI

V200R005C00

CE6880EI

V200R005C10

CE6850HI/CE6850U-HI/CE6851HI/CE6855HI/CE6856HI/CE6870-24S6CQ-EI/CE6870-48S6CQ-EI

V200R005C00

CE6857EI

V200R005C10

CE6870-48T6CQ-EI/CE6860EI

V200R005C00

CE6875EI

V200R005C00

CE6865EI

V200R005C00

CE5880EI

V200R005C10

IPv6 VXLAN path detection
Table 13-6 Products and minimum version supporting path detection

Product Model

Minimum Version Required

CE6875EI

V200R003C00

Feature Limitations

Common limitations of path detection:

  • The Agile Controller (AC) in this document is the Agile Controller-DCN.
  • Path detection packets are not terminated by the switch, but are forwarded to the destination server or VM.
  • When path detection and multiple other services need to be configured together, the path detection service may fail to be delivered because of insufficient ACL resources. For services that can be configured together with path detection, see "Using VXLAN/EVPN with Other Services" in CloudEngine 12800, 12800E, 8800, 7800, 6800, and 5800 Series Switches ACL Technical Topics.

Limitations of IPv4 path detection:

  • The IPv4 path detection function can detect only the traffic path between any two devices when no tunnel is configured or a VXLAN tunnel is configured.

  • After the path detection function is enabled on a VXLAN decapsulation device, this function may affect common TCP/UDP/ICMP packets encapsulated in VXLAN packets. As a result, the server may receive duplicate TCP/UDP/ICMP packets.
  • In an SVF on VXLAN, inter-VM path detection is not supported.
  • On the CE6880EI and CE5880EI, the ip path detection enable and ip path detection packet-format commands cannot be configured at the same time.
  • On the CE6880EI and CE5880EI, the IPv4 path detection function cannot identify ICMP detection packets. Therefore, you must select UDP or TCP when constructing detection packets.
  • If DSCP-based IPv4 path detection is enabled, plan the DSCP value that is used to identify detection packets, and ensure that the DSCP values are not used by any other service traffic.
Limitations of DSCP-based IPv6 path detection:
  • The DSCP-based IPv6 path detection function can detect only the traffic path between any two VMs on the IPv6 over IPv4 VXLAN network.
  • If DSCP-based IPv6 path detection is enabled, plan the DSCP value that is used to identify detection packets, and ensure that the DSCP values are not used by any other service traffic.
  • After the path detection function is enabled on a VXLAN decapsulation device, this function may affect common TCP/UDP/ICMP packets encapsulated in VXLAN packets. As a result, the server may receive duplicate TCP/UDP/ICMP packets.
  • In an SVF on VXLAN, inter-VM path detection is not supported.
Limitations of IPv6 VXLAN path detection:
  • IPv6 VXLAN path detection can detect only traffic paths between VTEPs, not VMs.

  • Only CE6875EI supports IPv6 VXLAN path detection.

Limitations of connectivity detection:

  • The ip path detection packet-format icmp src-ip src-ip-address dst-ip dst-ip-address and ip path detection packet-format arp [ src-mac src-mac-address ] [ dst-mac dst-mac-address ] src-ip src-ip-address dst-ip dst-ip-address commands cannot be used together on the CE6870EI and CE6875EI, and can be used together on other models.

  • On the CE6880EI and CE5880EI, the ip path detection enable and ip path detection packet-format commands cannot be configured at the same time.
  • Connectivity detection packets are not terminated by the switch, but are forwarded to the destination server or VM.