Configuration Guide - Network Management and Monitoring

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, NETCONF, OpenFlow, LLDP, NQA, Mirroring, Packet Capture, Packet Trace, Path and Connectivity Detection Configuration, NetStream, sFlow, and iPCA.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Default Settings for iPCA

Default Settings for iPCA

Table 16-5 Default settings of performance measurement

Parameter

Default Setting

UDP port used for communication between DCPs and MCP 65030
Color bit for packet loss measurement Bit 6 of the ToS field in IP packet header
Color bit for delay measurement Bit 7 of the ToS field in IP packet header
Measurement interval 10s