Configuration Guide - Virtualization

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document describes the configurations of virtualization, including stack and SVF.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling the Single-Homing Alarm Function for Leaf Switches

Enabling the Single-Homing Alarm Function for Leaf Switches

Context

On a network requiring high reliability, each leaf switch needs to connect to multiple parent switches. After the single-homing alarm function is enabled, the SVF system generates an alarm if a leaf switch connects to only one parent switch.

Procedure

  1. Run the system-view command to enter the system view.
  2. Run the stack command to enter the stack management view.
  3. Run the leaf single-homed alarm enable command to enable the single-homing alarm function for leaf switches.

    By default, the single-homing alarm function is disabled.

  4. Run the commit command to commit the configuration.