RESTful API Reference

CloudEngine 12800 and 12800E V200R005C10

This document describes the OPS APIs supported by the device, including OPS-supported operations, request examples, elements in the requests, response examples, elements in the responses, and response status codes.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Query Flapping Suppression Parameters on an Interface

Query Flapping Suppression Parameters on an Interface

Operation

URI

Description

GET

/ifm/interfaces/interface/ifControlFlap

Query flapping suppression parameters on an interface.

  • Request example
    <?xml version="1.0" encoding="UTF-8"?>
    <interfaces>
        <interface>
            <ifName>10GE1/0/1</ifName>
            <ifControlFlap/>
        </interface>
    </interfaces>

    Table 9-31 describes elements in requests.

    Table 9-31 Elements

    Element

    Description

    ifName

    Specifies an interface name.

    ifControlFlap

    Specifies whether the interface status is suppressed.

  • Response example (XML format)
    <?xml version="1.0" encoding="UTF-8"?>
    <interfaces>
         <interface>
              <ifName>10GE1/0/1</ifName>
              <ifControlFlap>
                <ifSuppress>2000</ifSuppress>
                <ifReuse>750</ifReuse>
                <ifDecayOk>54</ifDecayOk>
                <ifDecayNg>54</ifDecayNg>
                <ifCeiling>6000</ifCeiling>
                <ifCtrlFlapEnbl>false</ifCtrlFlapEnbl>
              </ifControlFlap>
         </interface>
    </interfaces>

    Table 9-32 describes elements in responses.

    Table 9-32 Elements

    Element

    Description

    ifName

    Specifies an interface name.

    ifControlFlap

    Specifies whether the interface status is suppressed.

    ifSuppress

    Specifies a suppression threshold. The value must be larger than the reuse value and smaller than the ceiling value.

    ifReuse

    Specifies an alarm reuse threshold. The reuse value must be smaller than the suppression threshold.

    ifDecayOk

    Specifies the time (in seconds) that the penalty value takes to decrease to half when an alarm clearance signal is received.

    ifDecayNg

    Specifies the time (in seconds) that the penalty value takes to decrease to half when an alarm generation signal is received.

    ifCeiling

    Specifies an alarm ceiling threshold. The ceiling value must be larger than the suppression threshold.

    ifCtrlFlapEnbl

    Specifies the enabling flag of interface status suppression.

    Table 9-33 describes status codes in responses.

    Table 9-33 Status codes

    Status Code

    Description

    200 OK

    The operation succeeded.

    400 Bad Request

    The request operation failed because the request is incorrect in syntax or the information attribute in the request is incorrect.

    500 Internal Server Error

    The request operation failed because of internal errors in services or unidentified processing errors.

Translation
Download
Updated: 2019-04-03

Document ID: EDOC1100075372

Views: 10510

Downloads: 16

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next