TR-069 Configuration Parameter Description

HUAWEI IP Phone 7920 and 7960 V600R019C10

Describes the TR-069 configuration parameters.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Device.ComCfg.SysConf.

Device.ComCfg.SysConf.

Table 1-35 Device.ComCfg.SysConf.

Name

Parameter on the ACS Side

Type

Setting

Parameter Writable on the ACS Side

DormancyTime

Device.UserInterface.X_001E10_SysConf.X_001E10_DormancyTime

unsignedInt

Value: 1, 2, 3, 5, 10, or 30

  • 1: 1 minute
  • 2: 2 minutes
  • 3: 3 minutes
  • 5: 5 minutes
  • 10: 10 minutes
  • 30: 30 minutes

Default value: 5

W

ChangeEnable

Device.UserInterface.X_001E10_SysConf.X_001E10_ChangeEnable

boolean

Value: 0 or 1

  • 0: disable
  • 1: enable

Default value: 1

W

ChangeTime

Device.UserInterface.X_001E10_SysConf.X_001E10_ChangeTime

unsignedInt

Value: 10, 30, 60, 120, 180, 300, 600, 1800

  • 10: 10s
  • 30: 30s
  • 60: 1 minute
  • 120: 2 minutes
  • 180: 3 minutes
  • 300: 5 minutes
  • 600: 10 minutes
  • 1800: 30 minutes

Default value: 60

W

ScreenSaverEnable

Device.UserInterface.X_001E10_SysConf.X_001E10_ScreenSaverEnable

boolean

Value: 0 or 1

  • 0: disable
  • 1: enable

Default value: 1

W

ScreenSaverWaitTime

Device.UserInterface.X_001E10_SysConf.X_001E10_ScreenSaverWaitTime

unsignedInt

Value: 60, 120, 180, 300, 600, and 1800

  • 60: 1 minute
  • 120: 2 minutes
  • 180: 3 minutes
  • 300: 5 minute
  • 600: 10 minutes
  • 1800: 30 minutes

Default value: 120

W

BreathingLightEnable

Device.UserInterface.X_001E10_SysConf.X_001E10_BreathingLightEnable

boolean

Value: 0 or 1

  • 0: disable
  • 1: enable

Default value: 1