Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00DB0001 Full LUN Copy Is Faulty

0xF00DB0001 Full LUN Copy Is Faulty

Description

A full LUN copy is faulty due to a source LUN or target LUN fault, or link down between storage devices.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF00DB0001

Alarm

Critical

Yes

Impact on the System

Except deleting the LUN copy and deleting the target LUN, other operations related to the LUN copy cannot be performed.

Possible Causes

  • Links for LUN copy between storage arrays are unavailable.
  • The source LUN or target LUNs are abnormal.
  • The disk domain is faulty.

Procedure

  1. Check whether an alarm indicating the disk domain fault is generated.

    1. If yes, handle the alarm with recommended actions. If the alarm persists=> Step2.
    2. If no=> Step2.

  2. Check whether the links between storage arrays are down.

    1. If yes, replace the faulty optical fibers or network cables. If the alarm persists=> Step3.
    2. If no=> Step3.

  3. Collect related information and contact technical support engineers.