Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF4045002B AD Domain Service Is Unavailable

0xF4045002B AD Domain Service Is Unavailable

Description

The connection to the AD domain service of a vStore is interrupted.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF4045002B

Alarm

Major

Yes

Impact on the System

The AD domain user cannot access the CIFS share.

Possible Causes

  • The network connectivity between the device and AD domain of a vStore is abnormal.
  • The AD domain of a vStore has been disabled.

Procedure

  1. Check whether the service network connectivity between the device and AD domain is normal.

    1. If yes=> Step2.
    2. If no, contact the network administrator to rectify the network fault. If the fault is recovered,no further action is required. If the fault persists=> Step2.

  1. Check whether services of the AD domain are stopped.

    1. If no=> Step3.
    2. If yes, start services of the AD domain. If the fault is rectified, no further action is required. If the fault persists=> Step3.

  2. Contact technical support engineers.