Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0x200F4045000F No Domain Controller Is Available

0x200F4045000F No Domain Controller Is Available

Description

A NAS node is disconnected from all domain controllers.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0x200F4045000F

Alarm

Major

Yes

Impact on the System

Domain authentication fails. Domain services are affected.

Possible Causes

  • The AD domain controller is shut down.
  • The device is incorrectly communicating with the AD domain controller.

Procedure

  1. Check the status of the AD domain controller.

    1. Check whether the AD domain controller is started.
    2. Start the AD domain controller. Then check whether the alarm is cleared.If yes, no further action is required.

  2. Check the network connectivity between the device and AD domain controller.

    1. Check whether the device is correctly communicating with the AD domain controller.
    2. Contact the network administrator to rectify the network fault. Then check whether the alarm is cleared.If yes, no further action is required.

  3. Contact technical support engineers.