Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00E0003D Failed To Initiate Authentication To The Remote Device In Negotiation Mode

0xF00E0003D Failed To Initiate Authentication To The Remote Device In Negotiation Mode

Description

The local array failed to initiate authentication to the remote device in negotiation mode.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF00E0003D

Alarm

Warning

Yes

Impact on the System

This issue has an impact on the configuration of HyperMetro and DR Star features on DeviceManager. For example, authentication fails when a HyperMetro domain is created.

Possible Causes

The machine-machine account information of the remote device has been changed. The information about the remote device machine-machine account that is encrypted and saved on the local array expires.

Procedure

  1. Obtain and record the machine-machine account information of the remote device.
  2. Run the "change remote_device user_password" command to modify the information about the remote device machine-machine account that is encrypted and saved on the local array. If the alarm persists=> Step3.
  3. Collect related information and contact technical support engineers.