OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF01070019 Configuration Module Of FS Remote Replication VStore Pair Is Disconnected

0xF01070019 Configuration Module Of FS Remote Replication VStore Pair Is Disconnected

Description

The local storage array of FS remote replication vStore pair is disconnected from the remote storage array.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF01070019

Alarm

Warning

Yes

Impact on the System

The configurations of local storage array of FS remote replication vStore pair are inconsistent with those of the remote storage array. The working site of FS remote replication vStore pair cannot be switched over.

Possible Causes

  • The link is not stable.
  • The configuration specifications at the secondary end reach the upper limit (including local resource users, local resource user groups, number of members in local resource user groups, and cross-protocol user mapping rules).
  • The service load is too heavy.

Procedure

  1. Check whether the link is correctly connected.

    1. If yes=> Step2.
    2. If no, replace the FC optical fiber or network cable of the faulty link and ensure the stable link connectivity. Then, wait 10 minutes. If the alarm persists=> Step2.

  1. Check whether the secondary end configurations exceed the upper limit.

    1. If yes, delete the useless configurations. Then, wait 10 minutes. If the alarm persists=> Step3.
    2. If no=> Step3.

  2. Collect related information and contact technical support engineers.