No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF0CE0008 Controller Enclosure Temperature Exceeds The Upper Limit

0xF0CE0008 Controller Enclosure Temperature Exceeds The Upper Limit

Description

The working temperature of a controller enclosure exceeds the upper limit.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF0CE0008

Alarm

Major

Yes

Impact on the System

The temperature of the controller enclosure exceeds the normal working temperature, which may affect normal storage system running and decrease storage system performance.

Possible Causes

  • Fan modules are faulty.
  • Heat dissipation channels are blocked.
  • The ambient temperature exceeds the upper limit.

Procedure

  1. Check whether alarms are generated indicating fan module faults.

    1. If yes, replace the faulty fan modules. If the alarm persists=> Step2.
    2. If no=> Step2.

  1. Check whether heat dissipation channels are blocked.

    1. If yes, clear the heat dissipation channels. If the alarm persists=> Step3.
    2. If no=> Step3.

  2. Check whether the ambient temperature is too high.

    1. If yes, lower the existing air conditioners' temperature or add more air conditioners. If the alarm persists=> Step4.
    2. If no=> Step4.