Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF3C01000F The HyperMetro Pair Is Interrupted And The Local LUN Continues To Provide Services

0xF3C01000F The HyperMetro Pair Is Interrupted And The Local LUN Continues To Provide Services

Description

Local and remote devices of HyperMetro are disconnected.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF3C01000F

Alarm

Major

Yes

Impact on the System

Only one storage array can provide services, reducing system reliability.

Possible Causes

  • Links are unstable.
  • The storage pool is faulty or full.
  • The local LUN is faulty.
  • The remote LUN is faulty.
  • The disk domain is faulty.
  • The service load is too heavy.

Procedure

  1. Check whether an alarm about the remote device is generated.

    1. If yes, handle the alarm by taking recommended actions. If the alarm persists=> Step2.
    2. If no=> Step2.

  1. Check whether alarms are generated for the local and remote LUNs and their storage pools.

    1. If yes, handle the alarms by taking recommended actions. If the alarm persists=> Step3.
    2. If no=> Step3.

  2. Check whether an alarm is generated indicating disk domain faults.

    1. If yes, handle the alarm by taking recommended actions. If the alarm persists=> Step4.
    2. If no=> Step4.

  3. Check whether the HyperMetro recovery policy is manual recovery.

    1. If yes, synchronize the HyperMetro manually. If the alarm persists=> Step5.
    2. If no=> Step5.

  4. Check whether an alarm is generated indicating controller overload.

    1. If yes, handle the alarm by taking recommended actions. If the alarm persists=> Step6.
    2. If no=> Step6.

  5. Check whether an alarm is generated indicating degraded links.

    1. If yes, handle the alarm by taking recommended actions. If the alarm persists=> Step7.
    2. If no=> Step7.

  6. Check whether the member LUNs of the HyperMetro pair are in write-through status or write protection status.

    1. If yes, collect related information and contact technical support engineers.
    2. If no=> Step8.

  7. Collect related information and contact technical support engineers.