Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF0D10009 Interface Module Temperature Exceeds The Upper Limit

0xF0D10009 Interface Module Temperature Exceeds The Upper Limit

Description

The working temperature of an interface module exceeds the upper limit due to an ambient temperature increase or fan faults.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF0D10009

Alarm

Warning

Yes

Impact on the System

Services on the interface module may be abnormal.

Possible Causes

  • The ambient temperature exceeds the upper limit.
  • Fan modules are faulty.
  • The interface module is faulty.

Procedure

  1. Check whether alarms are generated indicating that the enclosure where the interface module resides overheats.

    1. If yes, perform recommended actions to handle alarms. If the alarm persists=> Step2.
    2. If no=> Step2.

  1. Check whether alarms are generated on the fan modules of the enclosure where the interface module resides.

    1. If yes, perform recommended actions to handle alarms. If the alarm persists=> Step3.
    2. If no=> Step3.

  2. Check whether alarms on the interface module faults are generated.

    1. If yes, replace the faulty interface module. If the alarm persists=> Step4.
    2. If no=> Step4.

  3. Collect all related information and contact technical support engineers.