No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00EA0016 Optical Module Temperature Is Below The Lower Limit

0xF00EA0016 Optical Module Temperature Is Below The Lower Limit

Description

The temperature of an optical module is below the lower limit.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF00EA0016

Alarm

Major

Yes

Impact on the System

N/A

Possible Causes

  • The ambient temperature is too low.
  • The optical module is faulty.

Procedure

  1. Check whether alarms are generated indicating the overcooling of the enclosure that houses the optical module.

    1. If yes, increase the existing air conditioners' temperature or add more air conditioners. If alarm Optical Module Temperature Is Below the Lower Limit persists=> Step2.
    2. If no=> Step2.

  2. Check whether alarms are generated indicating optical module faults.

    1. If yes, replace the faulty optical modules. If alarm Optical Module Temperature Is Below the Lower Limit persists=> Step3.
    2. If no=> Step3.

  3. Collect related information and contact technical support engineers.