Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF01050015 Switch Failed To Be Monitored

0xF01050015 Switch Failed To Be Monitored

Description

The system failed to monitor a switch.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF01050015

Alarm

Critical

Yes

Impact on the System

The system failed to monitor a switch.

Possible Causes

  • The switch is faulty.
  • The switch is powered off.
  • Cables are disconnected.

Procedure

  1. Check whether the power supply of the switch is abnormal.

    1. If yes, stabilize the external power supply. If the alarm persists=> Step2.
    2. If no=> Step2.

  2. Check whether the switch is faulty.

    1. If the switch running indicator is off or fault indicator is on, replace the switch. If the alarm persists=> Step3.
    2. If no=> Step3.

  3. Check the cable connection to the management network port.

    1. If the cable to the management network port is removed, reinsert the cable. If the alarm persists=> 3.2.
    2. If the cable to the management network port is damaged, replace the cable. If the alarm persists=> Step4.

  4. Check whether the network connection is abnormal.

    1. If yes, restore the network connection according to the installation guide. If the alarm persists=> Step5.
    2. If no=> Step5.

  5. Collect all related information and contact technical support engineers.