Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF3C010000 HyperMetro Is Disconnected

0xF3C010000 HyperMetro Is Disconnected

Description

Local and remote devices of HyperMetro are disconnected.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF3C010000

Alarm

Major

Yes

Impact on the System

Only one storage array can provide services, reducing system reliability.

Possible Causes

  • Links are unstable.
  • The storage pool is faulty or full.
  • The local LUN is faulty.
  • The remote LUN is faulty.
  • The service load is too heavy.
  • The disk domain is faulty.

Procedure

  1. Check whether cables are connected correctly.

    1. If yes=> Step2.
    2. If no, replace faulty optical fibers or network cables to ensure that all links work correctly. If the alarm Link Between a Host and Storage Array Is Unstable persists=> Step2.

  1. Check whether alarms are generated on local and remote LUNs and the storage pools that house the local and remote LUNs.

    1. If yes, handle the alarms by taking recommended actions. If the alarm Link Between a Host and Storage Array Is Unstable persists=> Step3.
    2. If no=> Step3.

  2. Check whether an alarm indicating the disk domain fault is generated.

    1. If yes, handle the alarm with recommended actions. If the alarm persists=> Step4.
    2. If no=> Step4.

  3. Collect all related information and contact technical support engineers.