Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF40450029 No LDAP/NIS Server Is Available

0xF40450029 No LDAP/NIS Server Is Available

Description

A NAS node is disconnected from all LDAP/NIS servers.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF40450029

Alarm

Major

Yes

Impact on the System

LDAP/NIS authentication fails. LDAP/NIS services are affected.

Possible Causes

  • The LDAP/NIS server is shut down.
  • The device is incorrectly communicating with the LDAP/NIS server.

Procedure

  1. Check the status of the LDAP/NIS server.

    1. Check whether the LDAP/NIS server is started.
    2. Start the LDAP/NIS server. Then check whether the alarm is cleared.If yes, no further action is required.

  1. Check the network connectivity between the device and LDAP/NIS server.

    1. Check whether the device is correctly communicating with the LDAP/NIS server.
    2. Contact the network administrator to rectify the network fault. Then check whether the alarm is cleared.If yes, no further action is required.

  2. Collect all related information and contact technical support engineers.