Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00CF0071 The Controller Fails To Be Powered On

0xF00CF0071 The Controller Fails To Be Powered On

Description

The controller fails to be powered on.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF00CF0071

Alarm

Critical

No

Impact on the System

  • The controller fails to be powered on. System reliability may be reduced.
  • The engine where the faulty controller resides loses redundancy protection. When the system write protection policy is enabled (enabled by default) and the system continues to work for more than the preset time (192 hours by default), the system enters the write protection mode.

Possible Causes

The exception in the power-on process causes the power-on failure.

Procedure

  1. Check whether an effective error code exists in the detailed information.

    1. If yes, find the troubleshooting measures according to the prompted error code.
    2. If no=> Step2.

  2. Collect the log information and contact technical support engineers to rectify the fault.

    1. If the write protection policy is enabled and the fault cannot be rectified within the preset period, run the "change system write_policy write_policy write_protect_time=xxx" command to change the effective period of the write protection policy. The engine has no redundancy protection, which may cause data reliability risks. Rectify the fault as soon as possible.
    2. If the system has entered the write protection mode but services need to be restored as soon as possible, run the "change system write_policy write_protect_switch=Disable" command to disable the write protection function of the system. The engine has no redundancy protection, which may cause data reliability risks. Rectify the fault as soon as possible. After the fault is rectified, restore the write protection function of the system in time.