Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF3C060003 HyperMetro VStore Pair Configuration Is Abnormally Interrupted

0xF3C060003 HyperMetro VStore Pair Configuration Is Abnormally Interrupted

Description

The HyperMetro vStore pair configuration between the local site and the remote site is abnormally interrupted.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF3C060003

Alarm

Major

Yes

Impact on the System

HyperMetro vStore pair local and remote configurations are inconsistent. The work station of HyperMetro vStore pair cannot be switched.

Possible Causes

  • The link is not stable.
  • The configuration specifications at the secondary site reach the threshold (local resource user, local resource user group, number of members in local resource user group, cross-protocol user mapping rules).
  • The service load is too heavy.

Procedure

  1. Check whether the link is correctly connected.

    1. If yes=> Step2.
    2. If no, replace the FC optical fiber or network cable of the faulty link and ensure the stable link connectivity. After the operation, wait 10 minutes. If the alarm persists=> Step2.

  1. Check whether the secondary site configuration exceeds the threshold.

    1. If yes, delete the useless configuration. After the operation, wait 10 minutes. If the alarm persists=> Step3.
    2. If no=> Step3.

  2. Collect related information and contact technical support engineers.