Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF000B011B FC Link Of Back-End Device Disconnected

0xF000B011B FC Link Of Back-End Device Disconnected

Description

The Fibre Channel link of a back-end device is interrupted.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF000B011B

Alarm

Major

Yes

Impact on the System

The NAS disk may have one link only, or go offline.

Possible Causes

  • The cable is not connected or is damaged.
  • The optical module or interface module is faulty.
  • The switch port is faulty, powered off, or its configurations are incorrect.
  • The back-end device is faulty or is powered off.

Procedure

  1. Check the switch status and configuration. If the cables on the switch are not connected, the optical module on the switch is faulty, the switch is faulty or powered off, or the configuration is incorrect, rectify the fault. If the alarm persists=> Step2.
  2. Check the status of the back-end device. If the cables on the back-end device are not connected, the optical module is faulty, the interface module is faulty, or the back-end device is faulty or powered off, rectify the fault. If the alarm persists=> Step3.
  3. Collect related information and contact technical support engineers.