Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0x100F0170008 Multi-Vendor Power Modules In The Same Enclosure

0x100F0170008 Multi-Vendor Power Modules In The Same Enclosure

Description

Power modules in the same enclosure are from different vendors.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0x100F0170008

Run Log

Warning

Yes

Impact on the System

The storage system fails to start.

Possible Causes

N/A

Procedure

  1. Replace all AC power supplies with DC ones or all DC power supplies with AC ones. All power supplies must be either DC or AC, and come from the same manufacturer.
Translation
Download
Updated: 2019-07-17

Document ID: EDOC1100076630

Views: 23358

Downloads: 5

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next