Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF01250000 A HyperVault Job Is Congested

0xF01250000 A HyperVault Job Is Congested

Description

During automatic backup, the last backup job is not completed.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF01250000

Alarm

Warning

No

Impact on the System

Data is not backed up to the secondary device on occasion.

Possible Causes

  • The remote backup task is suspended due to a link fault.
  • The configured backup time in the policy is insufficient for a backup job.
  • The time required by remote backup increases because the system resource load is too heavy and consequently data replication is slow.

Procedure

  1. Check whether some backup jobs of the HyperVault are suspended or interrupted.
  1. If yes, resume the suspended or interrupted backup jobs. Then check whether the alarm is cleared. If yes=> Step2.
  2. If no=> Step2.
  1. Modify the remote time policy and prolong the backup interval. If the alarm persists=> Step3.
  2. Check whether the load of system resources is too heavy.

    1. If yes, suspend or cancel other tasks that consume system resources. Then check whether the alarm is cleared. If yes=> Step4.
    2. If no=> Step4.

  3. Collect all related information and contact technical support engineers.
Translation