Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF3C010006 One Storage Array Of A HyperMetro Pair Is Isolated

0xF3C010006 One Storage Array Of A HyperMetro Pair Is Isolated

Description

The performance difference between the local and remote storage arrays of the HyperMetro pair exceeds the upper limit. Then one storage array is isolated.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF3C010006

Alarm

Major

Yes

Impact on the System

After the storage array is isolated, the HyperMetro pair is suspended. The storage array that has longer write I/O latency will stop providing services, decreasing reliability.

Possible Causes

  • The isolated storage array has slow disks.
  • The isolated storage array has an alarm indicating overheating batteries, fans, or CPUs.
  • The isolated storage array has disk or disk enclosure faults.
  • The storage pool where the member LUNs of the HyperMetro pair reside is faulty or full.
  • The service load is too heavy.

Procedure

  1. Check whether an alarm is generated indicating slow disks.

    1. If yes, handle the alarm by taking recommended actions. If the alarm persists=> Step2.
    2. If no=> Step2.

  1. Check whether an alarm is generated indicating overheating batteries, fans, or CPUs.

    1. If yes, handle the alarm by taking recommended actions. If the alarm persists=> Step3.
    2. If no=> Step3.

  2. Check whether an alarm is generated indicating a disk or disk enclosure fault.

    1. If yes, handle the alarm by taking recommended actions. If the alarm persists=> Step4.
    2. If no=> Step4.

  3. Check whether an alarm is generated indicating that the storage pool is faulty or full.

    1. If yes, handle the alarm by taking recommended actions. If the alarm persists=> Step5.
    2. If no=> Step5.

  4. Collect related information and contact technical support engineers.