Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF0125000E HyperVault Is Interrupted

0xF0125000E HyperVault Is Interrupted

Description

The HyperVault is interrupted.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF0125000E

Alarm

Major

No

Impact on the System

The HyperVault service works incorrectly.

Possible Causes

  • The link is unstable.
  • The disk domain is faulty.
  • The secondary device of the HyperVault is overloaded.
  • The primary file system of the HyperVault is faulty.
  • The secondary file system of the HyperVault is faulty.
  • The number of HyperVault copies reaches the upper limit.
  • The HyperVault service fails.

Procedure

  1. Check whether links are working properly.

    1. If yes=> Step2.
    2. If no, replace faulty optical fibers or network cables to ensure that all links work properly. If the alarm persists=> Step2.

  1. Check whether alarms are generated on the controller where the primary file system and secondary file system reside.

    1. If yes, handle the alarms by taking recommended actions. If the alarm persists=> Step3.
    2. If no=> Step3.

  2. Check whether an alarm is generated on the primary and secondary devices of the HyperVault indicating that the number of HyperVault copies reaches the upper limit.

    1. If yes, handle the alarm by taking recommended actions. If the alarm persists=> Step4.
    2. If no=> Step4.

  3. Check whether an alarm is generated on the primary and secondary devices of the HyperVault indicating that a HyerVault task fails.

    1. If yes, handle the alarm by taking recommended actions. If the alarm persists=> Step5.
    2. If no=> Step5.

  4. Check whether an alarm indicating the disk domain fault is generated.

    1. If yes, handle the alarm with recommended actions. If the alarm persists=> Step6.
    2. If no=> Step6.

  5. Collect all related information and contact technical support engineers.