Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF03300069 The Virtual Machine File System Is Abnormal

0xF03300069 The Virtual Machine File System Is Abnormal

Description

The virtual machine file system is abnormal.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF03300069

Alarm

Major

Yes

Impact on the System

The VM management system cannot work correctly.

Possible Causes

  • The LUN corresponding to the VM file system is faulty.
  • The LUN corresponding to the VM file system is removed from the LUN group.
  • The host corresponding to the VM file system is removed from the host group.
  • The initiator corresponding to the VM file system is removed from the host.
  • The host group or LUN group corresponding to the VM file system is removed from the mapping view.
  • The file system is faulty.

Procedure

  1. Check whether the LUN is normal.

    1. If yes=> Step2.
    2. If no, repair the LUN. If the alarm persists=> Step2.

  1. Check whether the LUN is removed from the LUN group.

    1. If yes=> add the LUN to the LUN group again. If the alarm persists=> Step3.
    2. If no=> Step3.

  2. Check whether the host is removed from the host group.

    1. If yes, add the host to the host group again. If the alarm persists=> Step4.
    2. If no=> Step4.

  3. Check whether the initiator is removed from the host.

    1. If yes, add the initiator to the host again. If the alarm persists=> Step5.
    2. If no=> Step5.

  4. Check whether the host group or LUN group is removed from the mapping view.

    1. If yes, add the host group or LUN group to the mapping view again. If the alarm persists=> Step6.
    2. If no=> Step6.

  5. Mount the VM file system again. If the alarm persists=> Step7.
  6. Collect related information and contact technical support engineers.