Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF4045000E Adding To An AD Domain Fails

0xF4045000E Adding To An AD Domain Fails

Description

A NAS cluster fails to be added to an AD domain.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF4045000E

Alarm

Major

No

Impact on the System

Domain authentication fails. Domain services are affected.

Possible Causes

  • The device is incorrectly communicating with the AD domain controller.
  • The DNS of the device is incorrectly configured.
  • The system time of the device is different from that of the AD domain controller.

Procedure

  1. Check the network connectivity between the device and AD domain controller.

    1. Check whether the device is correctly communicating with the AD domain controller.
    2. Contact the network administrator to rectify the network fault. Then check whether the alarm persists.If no, no further action is required.

  1. Check the DNS configuration of the device.

    1. Check whether the DNS of the device is incorrectly configured.
    2. Reconfigure the DNS. Then check whether the alarm persists.If no, no further action is required.

  2. Check the system time of the device and that of the AD domain controller.

    1. Check whether the difference between the system time of the device and that of the AD domain controller is less than 5 minutes.
    2. Ensure that the difference between the system time of the device and that of the AD domain controller is less than 5 minutes. Then check whether the alarm persists.If no, no further action is required.

  3. Contact technical support engineers.
Translation