Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00B0002 LUN Has A Medium Error

0xF00B0002 LUN Has A Medium Error

Description

A medium error occurs on a LUN in storage pool.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF00B0002

Alarm

Critical

No

Impact on the System

The reliability of data stored on the LUN decreases.

Possible Causes

Bad sectors or pages are detected on disks.

Procedure

  1. Check whether the LUN has a backup.

    1. If yes, restore data on the LUN from the backup LUN.
    2. If no=> Step2.
    3. If step1.1 has been performed, manually clear the alarm.

  2. Collect related information and contact technical support engineers.