Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00D80124 The Total Subscribed Capacity Of File Systems In The Storage Pool Exceeds The Capacity Of The Storage Pool

0xF00D80124 The Total Subscribed Capacity Of File Systems In The Storage Pool Exceeds The Capacity Of The Storage Pool

Description

The total subscribed capacity of file systems in the storage pool exceeds the capacity of the storage pool.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF00D80124

Alarm

Warning

Yes

Impact on the System

Capacity allocated to some file systems in the storage pool is insufficient.

Possible Causes

The total subscribed capacity of file systems in the storage pool exceeds the capacity of the storage pool.

Procedure

  1. Expand the capacity of the storage pool, reduce capacity of the file system, or delete the file system to ensure that the capacity of the storage pool is greater than or equal to the total subscribed capacity of file systems. If the alarm persists=> Step2.
  2. Collect related information and contact technical support engineers.