Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF0015001A Link Between A Host And Storage Array Is Down

0xF0015001A Link Between A Host And Storage Array Is Down

Description

The link between a host and storage array is down.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF0015001A

Alarm

Major

Yes

Impact on the System

The storage array reliability decreases, causing service interruption risks.

Possible Causes

  • Cables between the host and the storage array are removed or damaged.
  • Optical modules are faulty.
  • The front-end port is faulty.
  • Interface modules are faulty.
  • Controllers are faulty.
  • The host HBA is faulty.
  • Switches are faulty.

Procedure

  1. Check the HBAs on the host. Contact the HBA provider for help when necessary. If the HBAs have no faults=> Step2.
  2. Check related switches. Contact the switch provider for help when necessary. If the switches have no faults=> Step3.
  3. Check the cables connecting the host and the storage array.

    1. If any cable is removed, reinsert it. If the alarm persists=> 3.2.
    2. Replace the cable. If the alarm persists=> Step4.

  4. Check whether alarms are generated indicating optical module faults.

    1. If yes, handle the alarms by taking recommended actions. If the alarm persists=> Step5.
    2. If no=> Step5.

  5. Check whether alarms are generated indicating port faults.

    1. If yes, handle the alarms by taking recommended actions. If the alarm persists=> Step6.
    2. If no=> Step6.

  6. Check whether alarms are generated indicating interface module faults.

    1. If yes, handle the alarms by taking recommended actions. If the alarm persists=> Step7.
    2. If no=> Step7.

  7. Check whether alarms are generated indicating controller faults.

    1. If yes, handle the alarms by taking recommended actions. If the alarm persists=> Step8.
    2. If no=> Step8.

  8. Collect related information and contact technical support engineers.