Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF406E0018 NDMP Restoration Task Failed

0xF406E0018 NDMP Restoration Task Failed

Description

An NDMP restoration task failed.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF406E0018

Run Log

Warning

No

Impact on the System

The NDMP current restoration task failed.

Possible Causes

  • The restoration path is invalid.
  • The number of tasks reaches the upper limit.
  • Other causes.

Procedure

  1. Check whether the backup software is correctly configured.

    1. If yes=> Step2.
    2. If no, configure the backup software parameters again. If the fault is recovered, no further action is required. If the fault persists=> Step2.

  1. Check whether the network is normal.

    1. If yes=> Step3.
    2. If no, connect the cables again. If the fault is recovered,no further action is required. If the fault persists=> Step3.

  2. Check whether the tape library is normal.

    1. Ensure that the tape drive is in the up state. If the fault is recovered, no further action is required. If the fault persists=> 3.2.
    2. Ensure that the tape library is intact. If the fault is recovered, no further action is required. If the fault persists=> Step4.

  3. Collect related information and contact technical support engineers.